3 Phase 400V/50Hz/1500rpm/400kw Open Style Diesel Generator Set/Generating Set/Genset

Product Details
After-sales Service: Provide Technical Support
Warranty: 12month
Type: Basic Diesel Generator
Gold Member Since 2006

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
2
Year of Establishment
2012-03-21
  • 3 Phase 400V/50Hz/1500rpm/400kw Open Style Diesel Generator Set/Generating Set/Genset
  • 3 Phase 400V/50Hz/1500rpm/400kw Open Style Diesel Generator Set/Generating Set/Genset
  • 3 Phase 400V/50Hz/1500rpm/400kw Open Style Diesel Generator Set/Generating Set/Genset
  • 3 Phase 400V/50Hz/1500rpm/400kw Open Style Diesel Generator Set/Generating Set/Genset
  • 3 Phase 400V/50Hz/1500rpm/400kw Open Style Diesel Generator Set/Generating Set/Genset
  • 3 Phase 400V/50Hz/1500rpm/400kw Open Style Diesel Generator Set/Generating Set/Genset
Find Similar Products

Basic Info.

Model NO.
SG550
Installation Method
Fixed
Stroke
Four Stroke
Cooling Method
Water Cooling
Output Type
AC Three Phase
Speed
HSS
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew, 400kw Diesel Genset
Landuse Type of Unit
Ordinary
Excitation Mode
AC Rotating Exciter
Item Name
Diesel Generator Set
Gen-Set Model
Sg550
Prime Power(Kw/kVA)
400/500
Standby Power(Kw/kVA)
440/550
Engine Model
Kta19-G3a
Alternator Model
Hci544D
Overall Size
3600 X 1350 X 1910
Weight (Kg)
4240
Bore and Stroke(mm)
159 X 159
AVR Model
As440
Transport Package
Wooden Case or Plywood Case (Optional)
Specification
400KW Diesel Generator Set
Trademark
AVESPEED
Origin
China
Production Capacity
500/Month

Product Description

Three phase 400V/50Hz/1500rpm/400kw open style diesel generator set
 
Standard Features:
1.All generator set comply with international design and quality standards,such as ISO8528(GB/T2820-97),ISO3046,BS.EN60034, BS5000,IEC34-1,GB755,VDE0530,CSA22-2,AS1359, and so on.

2. Engine and alternator coupled with the compact base of structure steel, equipped with exhaust silencer and radiator.

3.AVESPEED designed controller IS900 and multiple circuit breaker as a standard configuration for single unit.

4.One year limited warranty covers all systems and components.
>>Prime power(Unlimited Time Running)
This rating is applicable for supplying electrical power in lieu of commercially purchased power. 
Variable load should not exceed a 70% average of the prime power rating during any operating period of 250 hours, 
The total operating time at 100% prime power shall not exceed 500 hours per year and this model can supply 10% over-load power for 1 hour in 12 hours.
>>Standby power
There rating should be applied where reliable utility power is available. 
A standby rated engine should be sized for a maximum of an 80% average load factor and 200 hours of operation per year. 
No overload capability is available for this rating.

NOTE 1:
All data is based on:
1. Engine operating with fuel system, water pump, lubricating oil pump, air cleaner and exhaust silencer; 
not included are battery charging alternator, fan, and optional driven components.
2. Engine operating with fuel corresponding to grade No. 2-D per ASTM D975.
3. ISO 3046, Part 1, Standard Reference Conditions of:
  Barometric Pressure: 100 kPa (29.53 in Hg)
  Air Temperature : 25 degree centigrade; Altitude:110 m (361 ft); Relative Humidity:30%;
  Air Intake Restriction: 254 mm H2O (10 in H2 O);Exhaust Restriction : 51 mm Hg (2 in Hg).
4. Backed by worldwide service network.
N/A : Not Available;
TBD: To Be Determined;

NOTE 2:
1. Alternators meet the requirement of BS EN 60034 and the relevant section of other international standards such as BS5000, 
VDE 0530, NEMA MG1-32, IEC34, CSAC22.2-100, As1359,and other standards and certifications 
can be considered on request.
2. Brushless alternator with brushless pilot exciter for excellent load response.
3. Backed by worldwide service network.

Specifications of Diesel Generator Sets
 
Engine Model Specification KTA19-G3A  
BASIC TECHNICAL DATA  
Engine type 4-cycle,-/T=Natural /turbocharged,-/A/AA=-/water to air after-cooled/air-air after-cooled  
Cylinder arrangement   6cylinders vertical in-line  
Bore and stroke(mm) 159×159  
Compression ratio 13.9:1  
Displacement(L) 19  
Estimated total weight (dry)(kg)   1690  
Engine rated speed(rpm) 1500  
Prime power(kW).gross 448  
Standby power(kW).gross   504  
EXHAUST SYSTEM  
Air intake flow(L/sec).rate        TBD  
Exhaust flow ( L/sec ).rate 1434  
Exhaust temperature.rate  538  
Max. back pressure(mmHg) 76  
Diameter of exhaust pipe (mm) 127  
COOLING SYSTEM  
Coolant capacity(only engine)(L)    30  
FUEL CONSUMPTION  
Standby power(L/h) 102(kg/hr)  
100% prime power(L/h) 91(kg/hr)  
75% prime power(L/h) 70(kg/hr)  
50% prime power(L/h)   49(kg/hr)  
LUBRICATION SYSTEM  
Oil pan capacity(L) 50  
ELECTRIC SYSTEM  
Governor type Electronic  
Starter motor 24V  
Battery charging system 35A  
3 Phase 400V/50Hz/1500rpm/400kw Open Style Diesel Generator Set/Generating Set/Genset3 Phase 400V/50Hz/1500rpm/400kw Open Style Diesel Generator Set/Generating Set/Genset3 Phase 400V/50Hz/1500rpm/400kw Open Style Diesel Generator Set/Generating Set/Genset3 Phase 400V/50Hz/1500rpm/400kw Open Style Diesel Generator Set/Generating Set/Genset3 Phase 400V/50Hz/1500rpm/400kw Open Style Diesel Generator Set/Generating Set/Genset

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier