Three Phase 400V/50Hz/1500rpm/520kw Containerized Soundproof Type Diesel Generator Set/Generating Set/Genset with Ce Certificate

Product Details
Type: Self-Starting Diesel Generator
Installation Method: Fixed
Stroke: Four Stroke
Gold Member Since 2006

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
2
Year of Establishment
2012-03-21
Find Similar Products

Basic Info.

Model NO.
KTAA19-G6A
Cooling Method
Water Cooling
Output Type
AC Three Phase
Speed
HSS
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Ordinary
Excitation Mode
Static Exciter
Key Word
Diesel Generator Set
Prime Power(Kw/kVA)
520/650
Standby Power (Kw/kVA)
570/712
Overall Size(Mm)
6058 X 2438 X 2591(20ft)
Weights(Kg)
7170
Engine Model
Qsktaa19-G3
Alternator Model
Hci544f
Gen-Set Model
Sg712
AVR Model
As440
Maximum Over-Speed(Rev/Min)
2250
Transport Package
Export Wooden Case (Standard)
Specification
520KW/400V/50HZ/1500rpm
Trademark
AVESPEED
Origin
Beijing, China
Production Capacity
350/Month

Product Description

Three phase 400V/50Hz/1500rpm/520kw containerized soundproof type diesel generator set
 
Standard Features:
1.  All generator set comply with international design and quality standards, such as ISO8528(GB/T2820-97), ISO3046,
BS.EN60034, BS5000, IEC34-1, GB755, VDE0530, CSA22-2, AS1359, and so on.
  2.Engine and alternator coupled with the compact base of structure steel, equipped with exhaust silencer and radiator.
  3.AVESPEED designed controller IS900 and multiple circuit breaker as a standard configuration for single unit.
  4.One year limited warranty covers all systems and components
>>Prime power(Unlimited Time Running)
This rating is applicable for supplying electrical power in lieu of commercially purchased power. 
Variable load should not exceed a 70% average of the prime power rating during any operating period of 250 hours, 
The total operating time at 100% prime power shall not exceed 500 hours per year and this model can supply 10% over-load power for 1 hour in 12 hours.
>>Standby power
There rating should be applied where reliable utility power is available. 
A standby rated engine should be sized for a maximum of an 80% average load factor and 200 hours of operation per year. 
No overload capability is available for this rating.

Whole Features:
1)Whole hoisting and installation high strength low carbon steel welded bed plate.
2)Built-in shockproof system and advanced coating make it wear-resisting.
3)Features;Heavy load, durable 4 stroke water-cooled engine, excellent transient response

4) Valves each cylinder, stainless crankshaft, bolt, cast Iron Steel and replaceable humid cylinder liner.
5) Full control panel with power indicator light, oil light
6) Emergency shutdown for low oil pressure and high water temperature
7) Large bottom fuel tank ensures long working time
8) Optional AMF control panel

NOTE 1:
All data is based on:
1. Engine operating with fuel system, water pump, lubricating oil pump, air cleaner and exhaust silencer; 
not included are battery charging alternator, fan, and optional driven components.
2. Engine operating with fuel corresponding to grade No. 2-D per ASTM D975.
3. ISO 3046, Part 1, Standard Reference Conditions of:
  Barometric Pressure: 100 kPa (29.53 in Hg)
  Air Temperature : 25 degree centigrade; Altitude:110 m (361 ft); Relative Humidity:30%;
  Air Intake Restriction: 254 mm H2O (10 in H2 O);Exhaust Restriction : 51 mm Hg (2 in Hg).
4. Backed by worldwide service network.
N/A : Not Available;
TBD: To Be Determined;

NOTE 2:
1. Alternators meet the requirement of BS EN 60034 and the relevant section of other international standards such as BS5000, 
VDE 0530, NEMA MG1-32, IEC34, CSAC22.2-100, As1359, and other standards and certifications can be considered on request.
2. Brushless alternator with brushless pilot exciter for excellent load response.
3. Backed by worldwide service network.
Product packages:
Export wooden case (standard) or Plywood case (optional)

Specificatios of Gensets
 
Model SpecificationKTAA19-G6AQSKTAA19-G3 
BASIC TECHNICAL DATA 
Engine type4-cycle,T=turbocharged, AA= /air-air after-cooled 
Cylinder arrangement  6 cylinders vertical in-line 
Bore and stroke(mm)159×159159×159 
Compression ratio13.0:115.0:1 
Displacement(L)18.919 
Estimated total weight (dry)(kg)  19051900 
Engine rated speed(rpm)1500 
Prime power(kW).grossN/A574 
Standby power(kW).gross  610634 
EXHAUST SYSTEM 
Air intake flow(L/sec).rate       750775 
Exhaust flow ( L/sec ).rate20541975 
Exhaust temperature.rate 584505 
Max. back pressure(mmHg)7610.2kpa 
Diameter of exhaust pipe (mm)TBDTBD 
COOLING SYSTEM 
Coolant capacity(only engine)(L)   3041.6 
FUEL CONSUMPTION 
Standby power(L/h)150156 
100% prime power(L/h)127143 
75% prime power(L/h)96109 
50% prime power(L/h)  6477 
LUBRICATION SYSTEM 
Oil pan capacity(L)5084.4 
ELECTRIC SYSTEM 
Governor typeElectronicECM 
Starter motor24V24V 
Battery charging system35A35A 
 