Generator Set Electrical Performance Data | |||||
Voltage Regulation,Stead State:≤±2%; | |||||
Sudden Voltage Regulation:≤-15%-+20% | |||||
Voltage Waving:≤±0.5% | |||||
Line Voltage Waveform Sine Distortion Ratio:≤ 5% | |||||
Frequency Regulation,Stead State::≤5% | |||||
Sudden Frequency Regulation:≤17% | |||||
Frequency Waving:≤0.9% | |||||
Recovery Time:≤5s | |||||
2 Design Principles / Scope of Supply | |||||
2.1 Design Principles | |||||
Generator use gas fuel as power supply and thermal dynamic conversion from spark ignition engine. Equipped with cooling,lubrication,fuel supply,control,power output,parallel gensets,base frame system which is a completed power output equipment. Low voltage,high pressure gas fuel is acceptable. | |||||
Gas engine and flange-mounted alternator (SAE housing) are connected via a torsionally resilient coupling and resiliently mounted to a rigid, welded steel base frame. Between them there is vibration dampers for eliminating vibration. | |||||
Genset controllers integrated on the base frame,adopting DeepSea or ComAp generator set controlling module | |||||
Gas valves integrated on the base frame,gas valves including:pressure gage ,filter,pressure maintaining valve,safe solenoid,flame arrestor | |||||
Gas Engine:Cummins NTAA855 engine,equipped with multi-sequential ignition engine management control system,one high energy ignition coin per cylinder,gas dedicated speed governor (WOODWARD),proportional gas mixer,exhaust gas turbocharge,air/air intercooler | |||||
Alternator:Marathon/USA brushless self excitation AC synchronism alternator with PMG function | |||||
Skid Mounted Generator Set | |||||
2.3 Engine Specifications | |||||
Engine Producer / Model | CCEC Cummins | NTAA855 | |||
Gas inlet System | Exhaust Gas Turbo,Air/Air Cooling, | ||||
Ignition System | Canada AFS-CDI multi-sequential ignition engine management control system | ||||
Speed Governor System | USA WOODWARD series integrated gas dedicated speed governor | ||||
Air-Gas Mixing System | USA IMPCO proportional mixer.can realize lean burn. | ||||
Cylinder Arrangement | 6 in line ,water cooling,2 valves,basin type combustion room | ||||
Displacement liter | 14 | ||||
Bore×Stroke mm | 140 | 152 | |||
Compression Ratio | 10:01 | ||||
Rated rpm | 1500 | ||||
Max.Standby Power at Rated RPM KW | 160 | ||||
Exhaust System | |||||
Max Back Pressure Kpa | 10 | ||||
Gas Inlet System | |||||
Air Flow liter/sec. | _ | ||||
Fuel Consumption System | |||||
100%(prime power)load m3/ h | 0 | ||||
75% (prime power)load:m3/ h | 0 | ||||
50% (prime power)load:m3/ h | 0 | ||||
Lubrication System | |||||
Minimum Lubrication Capacity liter | 36 | ||||
Minimum Oil Pressure @ Rated Speed kPa | 241 | ||||
Cooling System | |||||
Engine Coolant Capacity liter | 20.8 | ||||
Thermostat Open Temperature ºC | 82-93 | ||||
Maximum Water Temperature ºC | 104 | ||||
Radiator Coolant Capacity liter | 49 | ||||
Genset Running Requirements: | |||||
Gas Pipe Pressure kPa | 3~8 | ||||
Pipe Pressure Conversion Rate kPa/min | ≤ 1 | ||||
Methane Volume Content | ≥55%,Conversion Rate≤2%/min | ||||
Methane number | ≥90 | ||||
Heat Value MJ/Nm3 | ≥20 | ||||
H2S Content mg/Nm3 | ≤15-20 | ||||
NH3 Content mg/Nm3 | ≤20 | ||||
Impurities Content mg/Nm3 | ≤30 | ||||
Impurities Size μm | ≤5 | ||||
Water Content g/Nm3 | ≤40, no free water | ||||