150kw/50Hz/60Hz Natural Gas/Syngas/ Biogas Generator Set/Generating Sets

Product Details
After-sales Service: Provide Technical Support
Warranty: 12months
Output Type: AC Three Phase
Gold Member Since 2006

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
2
Year of Establishment
2012-03-21
  • 150kw/50Hz/60Hz Natural Gas/Syngas/ Biogas Generator Set/Generating Sets
  • 150kw/50Hz/60Hz Natural Gas/Syngas/ Biogas Generator Set/Generating Sets
  • 150kw/50Hz/60Hz Natural Gas/Syngas/ Biogas Generator Set/Generating Sets
  • 150kw/50Hz/60Hz Natural Gas/Syngas/ Biogas Generator Set/Generating Sets
  • 150kw/50Hz/60Hz Natural Gas/Syngas/ Biogas Generator Set/Generating Sets
  • 150kw/50Hz/60Hz Natural Gas/Syngas/ Biogas Generator Set/Generating Sets
Find Similar Products

Basic Info.

Model NO.
NTAA855
Gas Source
Biogas
Certification
CE, ISO, CCC
Power
50-200kW
Standard
Standard
Key Words
150kw Natural Gas Genset
Transport Package
Woodcase
Specification
150KW
Trademark
AVESPEED
Origin
China
Production Capacity
2000PCS Per Month

Product Description

150kw/50Hz/60Hz Natural Gas/Syngas/ Biogas Generator Set/Generating Sets150kw/50Hz/60Hz Natural Gas/Syngas/ Biogas Generator Set/Generating Sets150kw/50Hz/60Hz Natural Gas/Syngas/ Biogas Generator Set/Generating Sets150kw/50Hz/60Hz Natural Gas/Syngas/ Biogas Generator Set/Generating Sets150KW Natural Gas/biogas generator set/generating set 
    Generator Set Electrical Performance Data
Voltage Regulation,Stead State:≤±2%;
Sudden Voltage Regulation:≤-15%-+20%
Voltage Waving:≤±0.5%
Line Voltage Waveform Sine Distortion Ratio:≤ 5%
Frequency Regulation,Stead State::≤5%
Sudden Frequency Regulation:≤17%
Frequency Waving:≤0.9%
Recovery Time:≤5s
           
2       Design Principles / Scope of Supply                                                                     
2.1  Design Principles
Generator use gas fuel as power supply and thermal dynamic conversion from spark ignition engine. Equipped with cooling,lubrication,fuel supply,control,power output,parallel gensets,base frame system which is a completed power output equipment. Low voltage,high pressure gas fuel is acceptable.
  Gas engine and flange-mounted alternator (SAE  housing) are connected via a torsionally resilient coupling and resiliently mounted to a rigid, welded steel base frame. Between them there is vibration dampers for eliminating vibration.
 Genset controllers integrated on the base frame,adopting DeepSea or ComAp generator set controlling module 
 Gas valves integrated on the base frame,gas valves including:pressure gage ,filter,pressure maintaining valve,safe solenoid,flame arrestor
 Gas Engine:Cummins NTAA855 engine,equipped with multi-sequential ignition engine management control system,one high energy ignition coin per cylinder,gas dedicated speed governor (WOODWARD),proportional gas mixer,exhaust gas turbocharge,air/air intercooler
  Alternator:Marathon/USA  brushless self excitation AC synchronism alternator with PMG function 
  Skid Mounted Generator Set
           
 
2.3   Engine Specifications                                                                          
Engine Producer / Model CCEC Cummins       NTAA855
Gas inlet System Exhaust Gas Turbo,Air/Air Cooling, 
Ignition System Canada AFS-CDI multi-sequential ignition engine management control system
Speed Governor System USA WOODWARD  series integrated gas dedicated speed governor 
Air-Gas Mixing System USA IMPCO proportional mixer.can realize lean burn. 
Cylinder Arrangement 6 in line ,water cooling,2 valves,basin type combustion room
Displacement liter 14
Bore×Stroke  mm 140 152      
Compression Ratio 10:01        
Rated rpm 1500        
Max.Standby Power at Rated RPM  KW 160        
Exhaust System           
Max Back Pressure Kpa 10        
Gas Inlet System          
Air Flow  liter/sec. _        
Fuel Consumption System           
100%(prime power)load  m3/ h 0        
75% (prime power)load:m3/ h 0        
50% (prime power)load:m3/ h 0        
Lubrication System          
Minimum Lubrication Capacity  liter 36        
Minimum Oil Pressure @ Rated Speed kPa 241        
Cooling System          
Engine Coolant Capacity liter 20.8        
Thermostat Open Temperature  ºC 82-93        
Maximum Water Temperature ºC 104        
Radiator Coolant Capacity liter 49        
Genset Running Requirements:          
Gas Pipe Pressure  kPa 3~8        
Pipe Pressure Conversion Rate  kPa/min ≤ 1        
Methane Volume Content ≥55%,Conversion Rate≤2%/min        
Methane number ≥90        
Heat Value MJ/Nm3 ≥20         
H2S Content mg/Nm3 ≤15-20        
NH3 Content mg/Nm3 ≤20        
Impurities Content  mg/Nm3 ≤30        
Impurities Size μm ≤5        
Water Content g/Nm3 ≤40, no free water        
           
*Overload must reliably be avoided by means of suitable external control systems (e.g. electronic output power control). 
 150kw/50Hz/60Hz Natural Gas/Syngas/ Biogas Generator Set/Generating Sets

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier