Nature of Source Flow: | Active Inverter |
---|---|
Phase: | Single or Three Phase |
Output Power: | 5kw |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | AVE-5KTL | |
PV side | ||
Max. PV power | 5200Wp | |
Max. permitted DC Voltage | 1000Vdc | |
Input short-circuit current | 2×15A | |
Max. permitted DC current | 2×12A | |
MPPT number/Input points of each MPPT | 1/2 | |
MPPT voltage range at full power | 225~800Vdc | |
PV Start Voltage | 250Vdc | |
MPPT efficiency | 99.90% | |
Max Inverter feedback Current to the Array | 0A | |
Grid side | ||
Rated output power | 5kW | |
Max.output current | 3×7.3A | |
THD of grid current | <3% | |
Power factor | >0.99(adj. ±0.9) | |
Max. Efficiency | 96.51% | |
European efficiency | 95.41% | |
Output voltage | 320~450Vac 3~ | |
Permitted grid frequency range | 47.5~51.5Hz | |
Nighttime power consumption | <1W | |
Grid monitoring | According to VDE4105 guidelines | |
communication interface | RS485/GPRS(optional) | |
Man-machine interface | LCD | |
Environmental conditions and safety | ||
Isolation | Transformerless | |
Protection level | IP65 | |
Cooling | Air cooling | |
Operating temperature range | -25~+60'C(above 50'Cneed derate operating ) | |
Relative humidity range | 15-95% (non condensing) | |
Mounting altitude | 2000m;above 2000m need derate operating | |
Noise emissions | <50dB | |
lEC/EN 62109-2;lEC 61727;lEC 62116;VDE-AR-N 4105(or CGC/GF004:2011);IEC/EN6100-6-2 ; IEC/EN6100-6-4 ; IEC/EN6100-3-3 ; ENEL-Guide(Italy);G83;AS/NZS3100.2;AS4777.2;AS4777.3;EN 50178;lEC/EN 62109-1; | ||
Mechanical Data | ||
Dimensions (W × H × D) | 400×540×195 mm | |
Weight | 30kg |