10000m3/H Flow 10m Head Lp (T) Type Long-Axis Vertical Drainage Pump/Vertical Propeller Pump/Dewatering Water/Vertical Turbine Punmps

Product Details
After-sales Service: Provide Technical Support
Warranty: 12months
Max.Head: >150m
Gold Member Since 2006

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
2
Year of Establishment
2012-03-21
  • 10000m3/H Flow 10m Head Lp (T) Type Long-Axis Vertical Drainage Pump/Vertical Propeller Pump/Dewatering Water/Vertical Turbine Punmps
  • 10000m3/H Flow 10m Head Lp (T) Type Long-Axis Vertical Drainage Pump/Vertical Propeller Pump/Dewatering Water/Vertical Turbine Punmps
  • 10000m3/H Flow 10m Head Lp (T) Type Long-Axis Vertical Drainage Pump/Vertical Propeller Pump/Dewatering Water/Vertical Turbine Punmps
  • 10000m3/H Flow 10m Head Lp (T) Type Long-Axis Vertical Drainage Pump/Vertical Propeller Pump/Dewatering Water/Vertical Turbine Punmps
  • 10000m3/H Flow 10m Head Lp (T) Type Long-Axis Vertical Drainage Pump/Vertical Propeller Pump/Dewatering Water/Vertical Turbine Punmps
  • 10000m3/H Flow 10m Head Lp (T) Type Long-Axis Vertical Drainage Pump/Vertical Propeller Pump/Dewatering Water/Vertical Turbine Punmps
Find Similar Products

Basic Info.

Model NO.
250 VCP4-95
Max.Capacity
>400 L/min
Driving Type
Motor
Impeller Number
Multistage Pump
Working Pressure
Low Pressure Pump
Influent Type of Impeller
Double-Suction Pump
Position of Pump Shaft
Vertical Pump
Pump Casing Combined
Verticaljoint Surface Pump
Mounting Height
Since Irrigation Centrifugal Pumps
Impeller
Open
Usage
Pump, Pumps, Condensate Pump, Slurry Pump, Circulating Pump, Vertical Turbine Pump
Key Word
Vertical Pump
Pump Type
1000lp(T)-10
Outlet Diameter(Mm)
1000
Capacity (M3/H)
10000
Head (M)
10
Speed (R/Min)
490
Efficiency (%)
85.2
Motor Power (Kw)
400
Transport Package
Poly Plastic Firm, Wooden Box or as Need
Specification
10000m3/h Head: 10m Vertical Turbine Pump
Trademark
AVESPEED
Origin
China
Production Capacity
2000sets/Month

Product Description

10000m3/H Flow 10m Head Lp (T) Type Long-Axis Vertical Drainage Pump/Vertical Propeller Pump/Dewatering Water/Vertical Turbine Punmps10000m3/H Flow 10m Head Lp (T) Type Long-Axis Vertical Drainage Pump/Vertical Propeller Pump/Dewatering Water/Vertical Turbine Punmps10000m3/H Flow 10m Head Lp (T) Type Long-Axis Vertical Drainage Pump/Vertical Propeller Pump/Dewatering Water/Vertical Turbine Punmps10000m3/H Flow 10m Head Lp (T) Type Long-Axis Vertical Drainage Pump/Vertical Propeller Pump/Dewatering Water/Vertical Turbine Punmps10000m3/h head 10m  LP(T) type long-axis vertical drainage pump/Vertical Turbine Pump/Dewatering Pump

General introduction and application:
LP Type Long-axis Vertical Discharge Pump is mainly used for pumping sewage or waste water which are non corrosive, at the temperature lower than 60Co and of which suspended substances are free of fibers or abrasive particles, content is less than 150mg/L.
On the basis of LP Type Long-axis Vertical Discharge Pump. LPT type is additionally fitted with muff armor tubing with lubricant inside, serving for pumping of sewage or waste water, which are at the temperature lower than 60Co and contain certain solid particles, such as scrap iron, fine sand, coal powder, etc.
LP(T) Type Long-axis Vertical Discharge Pump is of wide applicability in the fields of public work, steel and iron metallurgy, chemistry, paper-making, tapping water service, power station and irrigation and water conservancy, etc.

Operational conditions:
1. The temperature of medium shall not be higher than 60Co.
2. The medium shall be neutral and PH value between 6.5~8.5. If the medium is not consistent to the requirements, specify in the order list.
3. For LP type pump, the content of suspended substances in the medium shall be less than 150mg/L; For LPT type pump, the max. Diameter of solid particles in the medium shall be less than 2 mm and the content less than 2 g/L.
4. LPT type pump shall be connected with clean water or soapy water outside to lubricate the rubber bearing. For two-stage pump, lubricant pressure shall not be less than half of operational pressure.
5. The first stage impeller of pump shall be immersed in 0.5m above at min. Water level and generally it is suggested to be within 2~3 m.
6. The wellbore shall be straight.
7. Specify the depth of well or under-liquid depth of pump in the order list.
8. Special operational condition is subject to agreement or technical agreement.

Specifications of Vertical Turbine Pumps
Pump type Outlet diameter(mm) Capacity (m 3 /h) Head (m) Speed (r/min) Efficiency (%) Motor Power (KW)
1000LP(T)-4 1000 9500 4 485 87 185
1000LP(T)-7 10500 7 485 87.1 315
1000LP(T)-9 10000 9 490 84.5 355
1000LP(T)-10 10 85.2 400
1000LP(T)-13 13 85.3 500
1000LP(T)-16 16 85.6 630
1000LP(T)-18 18 85.8 710
1000LP(T)-20 20 86.4 800
1000LP(T)-7-X 10500 7 485 87.1 315
1000LP(T)-13-X 10000 13 490 85.3 500
1000LP(T)-17-X 17 85.5 710
1000LPTC-15 9000 15 84.5 560
1000LPTC-15-X 15 84.5 560
1000LPTC-20 20 590 86 710
1000LPTC-20-X 20 590 86 710
1200LP(T)-4 1200 13500 4 490 84.2 250
1200LP(T)-6 15000 6 87.4 355
1200LP(T)-9 14500 9 84.5 560
1200LP(T)-12 14500 12 85.2 710
1200LP(T)-14 14000 14 85.3 800
1200LP(T)-16 13000 16 86.6 800
1200LP(T)-18 15000 18 495 85.8 1000
1200LP(T)-20 16000 20 86.4 1250
 10000m3/H Flow 10m Head Lp (T) Type Long-Axis Vertical Drainage Pump/Vertical Propeller Pump/Dewatering Water/Vertical Turbine Punmps

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier