TL(R) Series FGD PumpGeneral:
Series of TL FGD pump is a single stage and single suction horizontal centrifugal pump. It is mainly used as the circulating pump for absorbent tower in FGD appliances. It has such features: Wide rang flowing capacity, high efficiency, high saving power. This series of pump is matched by tight structure X bracket which can save much space. Meanwhile our company develops many kinds of material targeted on the pump for FGD.
Technology Features:The pump wet parts are designed by advanced CFD Flowing Simulating Analysis Techniques to ensure its design reliable and its working effective.
It can change the impeller's position in pump casing by adjusting the bearing assembly to keep the pump working high efficiently all the time.
This kind of pump adopts back pull-out structure, keeping it easy construction and easy maintenance. It doesn't need disassemble inlet & outlet pipeline.
Two sets of taper roller bearing is fixed in the end of the pump, the column roller bearing is equipped at driving end. The bearing is lubricated by oil. All these can improve the bearing working condition and greatly enhance its life.
Mechanical sealing is adopted integrating mechanical sealing which is specialized in FGD technology to ensure its operation.
Material Selection:AVESPEED has developed a new kind of specialized anti-wear and anti-corrosive material which possesses the duplex stainless steel's anti-corrosive property and the high chrome white iron's anti-abrasive property in FGD process.
In the rubber pump casing, impeller, suction cover/cover plate are all made of specialized anti-wear and anti-corrosive material; The material of front liner, back liner and back liner insert are natural rubber with light weight and natural, having excellent anti-corrosive property and low cost.
In metal pump casing, impeller, volute liner, suction plate and back plate are all made of specialized anti-wear and anti-corrosive material, the suction cover are made of ductile iron with rubber.
Type | Capacity | Head | Speed | Efficiency | NPSHr | Suction D/Discharge D |
M 3 /h | l/s | m | r/min | % | Mm/mm |
350TL(R) | 1600 | 444 | 25 | 960 | 82 | 4.5 | 350/400 |
400TL(R) | 2500 | 694 | 25 | 725 | 83 | 5.0 | 400/450 |
500TL(R) | 3750 | 1040 | 25 | 725 | 85 | 5.0 | 500/500 |
600TL(R) | 6300 | 1750 | 25.5 | 620 | 88 | 5.5 | 600/700 |
700TL(R) | 6840 | 1900 | 26 | 485 | 87 | 6.0 | 700/800 |
800TL(R) | 9360 | 2600 | 31 | 485 | 90 | 7.0 | 800/900 |
900TL(R) | 15000 | 4167 | 30 | 485 | 90 | 8.5 | 900/1000 |
1000TL(R) | 10440 | 2900 | 15 | 485 | 89 | 7.0 | 1000/1200 |