Nature of Source Flow: | Active Inverter |
---|---|
Phase: | Single |
Output Power: | 2.5kw |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Inverter model | AVE-N2K5 | AVE-N2K5-AU | AVE-N2K5-UK |
PV side | |||
Max.PV power | 2.75kWp | ||
Max.permitted DC Voltage | 450V | ||
Input short-circuit current | 16.9 | 16.9 | 15.0 |
Max.permitted DC current | 13.5A | 13.5A | 12A |
Input points | 1 | 1 | 2 |
MPPT voltage range | 200V-400V | 200V-400V | 140V-400V |
MPPT efficiency | 99.90% | ||
Grid side | |||
Rated output power | 2.5kW | ||
Max.output current | 10.9A | ||
Power factor | ≥0.99 | ||
Max.efficiency | 94.0% | ||
European efficiency | 93.5% | ||
Permitted grid voltage range | 180~260VAC | 200~270VAC | 207~264VAC |
Permitted grid frequency range | 47.5~51.5Hz | 45~55Hz | 47~50.5Hz |
THD of grid current | <3% | ||
Standby power consumption | 10W | ||
Nighttime power consumption | 0W | ||
Communication interface | RS485/GPRS(optional)/Ethernet(optional) | ||
Man-machine interface | LCD | ||
Environmental conditions and safety | |||
Protection level | IP65 | ||
Operating temperature range | -25~+60'C | ||
Cooling | Natural cooling | ||
Relative humidity range | 0-98% (non condensing) | ||
Noise emissions | <45dB @ 1m | ||
Isolated-method | low frequency transformer | ||
Dimensions(M/H/D) | 438/362/250(mm) | ||
Weight | 43.8Kg | 40Kg | 43.8Kg |
Meet the standards | EN 50178; DIN EN 62109-1; prlEC 62109-2;VDE 0126-1-1; EN61000-6-1:2007; EN61000-6-3 :2007; CGC/GF 001:2009 | IEC 62103; EN 50178; IEC/EN 62109-1; IEC/EN 62109-2; IEC/EN61000-3-3 :2007; AS/NZS 3100: 2009; AS4777.2: 2005; AS4777.3: 2005; | IEC 62103; EN 50178; IEC/EN 62109-1; IEC/EN 62109-2; IEC/EN61000-6-1:2007; IEC/EN61000-6-3:2007; G83/1-1/06.08 |