250KW Diesel/HFO Generator Set/Generating Sets/Genset
Our diesel generator set gone through the strict and complete test and detection. And during five years after-sales following and maintainance, this diesel generator set have been confirmed to be very sucessfully used by our customers.
All engine rating data based on ISO 3046/1;
Reference conditions: Ambient 25centigrade, Total Barometric Pressure: 100kPa, Relative humidity 30%, Intercooler coolant in: 25 centigrade;
Fuel characteristics: Related density: 0.84± 0.005, Lower heat value: 42700kj/kg, Consumption tolerance: +5%;
Power: An overload of 10% is permitted for one hour in every twelve hours of operation
Generator Model |
200GF |
250GF |
300GF |
350GF |
Rated Electrical Power(kw) |
200 |
250 |
300 |
350 |
Engine Model |
N6160ZLD2A |
N6160ZLD6A |
N8160ZLD2 |
N8160ZLD |
BorexStroke (mm) |
160x200 |
Engine Type |
4-Stroke, Inline, Direct Injection,Tubocharged, Intercooled |
Engine Capacity(kw) |
235 |
294 |
353 |
400 |
Engine Rev. (rpm) |
50Hz@1000 / 60Hz@1200 |
Fuel Consumption (L/h) |
52.4 |
65.5 |
78.6 |
93.8 |
Voltage |
Voltage no load adjustment range |
% |
95~105 |
Voltage fluctuation rate |
% |
±1 |
Stable voltage regulating rate |
% |
±2.5 |
Transient voltage regulating rate |
% |
±20~-15 |
Stabilizing time |
s |
1 |
Alternator Excitation method |
|
Brushless AVR |
Frequency |
Stable frequency (rev.) regulating rate |
% |
5 |
Frequency (rev.) fluctuation rate |
% |
±0.5 |
Transient frequency regulating rate |
% |
±10 |
Stabilizing time |
s |
< 5 |
Frequency regulating method |
|
Auto / Manual |
Protection |
Over speed |
115% Nr A, T, S |
Reverse P. |
-9.6% Pn A, T |
LO. P |
0.25MPa A, 0.15MPa T,S |
Over current |
130% In A, T |
FW T. |
80centigradeA, 85centigrade T,S |
Over voltage |
120% V A, T |
LO. T |
90centigradeA |
Over load |
110% In A |